This action is called after the entry in the criteria window. It is executed systematically whether there is a criteria window or not.
Standard process (interactive and batch mode)
It is used to carryout the last controls before the process. At this level, it is possible to :
Display an error message by setting GERR = 1 and entering a message in the variable GMESSAGE.
Interrupt the process by setting FIN = 1.
Return to entry ( just before the action AVANT_PAR ) by SAI = 1, when in interactive mode.
Assign a wait message by loading the variable TIT and displaying it by setting TMP = 1.
To display a wait message (Tempon) either assign a personalised text in the variable TIT, or choose a standard text by assigning a letter in the variable TIT. The default text is "operation in process...". Below is a list of common texts preceded by their code.
| V |
validation in process ... |
| F |
verification in process ... |
| L |
read in process ... |
| E |
write in process ... |
| A |
cancellation in process ... |
| R |
search in process ... |
| C |
calculation in process ... |
|
operation in process ... |