This inquiry is used to retrieve all the running times tracked in response to a WO selection or without WO.

Prerequisite

SEEREFERTTO Refer to documentation Implementation

Screen management

Header

The header information is used to specify the principal selection criteria for the inquiry being used.

  • Site: It is mandatory to enter a site.
  • Number range: this field is loaded by default with the number associated with the connected user. The ranges are used to filter the trackings based on the operators that performed them.
  • Tracking date range: The purpose here is to determine for which period the tracking of the time spent needs to be restored.
  • Tracking number range
  • WO number ranges

Tab Tracked times

The columns present in this grid depend on the setup of the screen code chosen.

By default this grid displays for the chosen selection criteria, a line by tracked time, showing the following:

  • Time type: (time spent on a WO or outside of a WO)
  • Achieved quantities, rejected achieved quantities
  • The times spent (running time, setup time) to achieve these quantities
  • The information on the routing, operation no., work center, routing code, WO code, within the framework of a tracking achieved in response to a WO.

Specific Buttons

Criteria

This button is used to access the additional selection criteria with respect to the criteria entered in the inquiry header.

It is possible to specify here criteria ranges:

  • Routings
  • Routing codes
  • Work centre
  • Operations
  • Project
  • Order
  • Time type: It is possible here to filter the various trackings presented according to their type (tracking related to a release or miscellaneous tracking)

Screen code : generally speaking, the inquiries can be set up. It is possible to call up customized inquiry screens via the screen code. This customization makes it possible to choose what are the information that should be shown in the screen and in what order it should be positioned in the grid.

Error messages

The only error messages are the generic ones.

Tables used

SEEREFERTTO Refer to documentation Implementation